ETAS Logo

ETAS - ES610 – A/D Module

  • Shortcut: Direct to the content of this page
  • Shortcut: Direct to the main navigation
  • To the end of the page
  • ETAS Products
    • Product Search
    • Applications & Solutions
      • ECU Function Development
      • ECU Software Development
      • ECU Testing (HiL)
      • ECU Calibration and Diagnostics
        • Measurement and ECU calibration
        • Integrated ECU Diagnostics
        • In-Vehicle Testing
        • Testing in the Lab / at the Test Bench

          Products for
          Testing in the Lab / at the Test Bench

          • ES1303 – A/D Board (16-CH, 100 kHz/CH)
          • ES1310 – D/A Board (8-CH)
          • ES411 - A/D Module with Sensor Supply (4-CH)
          • ES420 - Thermo Module (8-CH)
          • ES600 – Network Module
          • ES610 – A/D Module
          • ES611 – A/D Module with Sensor Supply
          • ES620 – Thermo Module
          • ES650 – Thermo and A/D Module
          • ES715 – Drive Recorder
          • ES780 – Heads-Up Display
          • LA4 – Lambda Meter
          • AWS2 – Signal Conditioning Unit
      • Service Diagnostics
    • Download Center
    • Support Center
    • Engineering Services
  • ETAS Group
  • » ETAS Products
  • » Applications & Solutions
  • » ECU Calibration and Diagnostics
  • » Testing in the Lab / at the Test Bench
  • » ES610 – A/D Module

ES610 – A/D Module

ES610

The ES610 measures analog voltages via 16 channels that are electrically isolated from each other and from the supply voltage to achieve a consistently high commonmode rejection, thereby ensuring maximum measuring accuracy even at low voltages.

The 16 bit resolution, which is available for two measuring ranges, allows high-precision measurements. The ES610 reaches a basic voltage measurement accuracy of up to 2 mV. To maintain the high precision even at large temperature fluctuations in daily operations, the measuring module has an ultra-low temperature coefficient of only 10 ppm/°C. Aside from the demand for high acquisition rates, it is also necessary to measure signals that often only vary very slowly. For such cases, the ES610 features a configurable acquisition rate and adjustable software filters that make it possible to reduce data during acquisition. The fastest acquisition rate is 2 kHz, independent of the number of active channels. Anti-aliasing 4th order filters in each channel ensure a clean analog/digital conversion without undesirable signal mixtures.

Functions at a Glance

  • 16 electrically isolated measuring channels for analog voltages
  • Measuring channels electrically isolated from the supply voltage
  • Adjustable acquisition rate per channel, max. 2 ksamples/s, min. 0.5 samples/s
  • Parameterized software filter for signal smoothing
  • High measurement accuracy through 16 bit resolution
  • Two selectable measuring ranges of ±10 V and ± 60 V
  • Data transfer to PC or ES600 via Ethernet
  • Rugged, functional metal housing
  • Hardware calibration service
Go to product family