Size and Weight |
|
Dimensions (HxWxD) | 51.5 x 40 x 142 mm / 2.0 x 1.6 x 5.6 in 37.5 x 40 x 129 mm / 1.5 x 1.6 x 5.1 in (tapered rear) |
Weight | 350 g / 0.77 lb |
Environment |
|
Temperature range | -40 °C to +120 °C (-40 °F to +248 °F) (operation) -40 °C to +125 °C (-40 °F to +257 °F) (storage) |
Protection class | IP67 (with cables connected) |
Altitude | Up to 5,000 m /16,400 ft |
Tested for | Mechanical shock, vibration, fall, temperature shock, temperature alteration, storage in humid-ity, salt fog attack, impact from flying rocks, according to DIN EN 60068 res. ISO 16750 |
Power supply |
|
Operating voltage | 5 V to 50 V DC (-40 °C to +85 °C / -40 °F to +185 °F), 6 V to 50 V DC (+85 °C to +120 °C / +185 °F to +248 °F) |
Power consumption (at 12 V) | 1.8 W typ. (operation without load), < 25 mW (stand-by) |
Reverse voltage protection; Load dump protection | Via Cables CBEP410 / 415 / 420/ 430 / 450 |
Host interface |
|
Ethernet connection and protocol | 100 Base-T, Full-Duplex required, XCP-on-UDP/IP |
IP address | Dynamic via INCA or configuration tool (default 192.168.40.44) |
Inputs |
|
Channels | 4, each with separate sensor supply |
Input measurement ranges (MR) | ±100 mV, ±1 V, ±10 V, ±60 V for diff. input voltage Vin |
Over voltage protection | ±100 V continuous, all MR |
Sampling rate | 0.5 Samples/s to 10 kSamples/s, configurable per channel [1] |
Resolution | 16 bit |
Anti-aliasing filter (in hardware) | 4th order Butterworth, 10 kHz corner frequency |
Software filter[1] | Digital FIR Butterworth 8th order, bypass possible, 5 kHz max. corner frequency |
Electrical isolation of inputs | Channel to channel and channel to supply |
Maximum common mode voltage | ±(100 V - [Vin]) channel to supply ground [1], Vin ≤±60 V |
Input impedance | > 2 MΩ II < 400 pF (±10 V, ±60 V) > 10 MΩ II < 300 pF ( ±1 V, ±100 mV) |
Sensor supply output |
|
Output voltage | +5 V to +15 V DC or Off, individually adjustable per channel, common ground with power supply, resolution < 1 mV |
Output current | ≤30 mA per channel, overcurrent protected (200 mA) |
Accuracy |
|
Ripple of output voltage | < 10 mV peak to peak |
Accuracy of output voltage | ±10 mV over the whole output voltage range |
Measurement Error (MR: 100 mV) | ±[0.1 % + 80 ppm/K x |T - 25 °C|] x MR ±0.1 % x Vin |
Measurement Error (MR: 1 V) | ±[0.05 % + 8 ppm/K x |T - 25 °C|] x MR ±0.05 % x Vin |
Measurement Error (MR: 10 V) | ±[0.03 % + 3.6 ppm/K x |T -25 °C|] x MR ±0.05 % x Vin |
Measurement Error (MR: 60 V) | ±[0.03 % + 60 ppm/K x |T - 25 °C|] x MR ±0.2 % x Vin |
Support by ETAS Software |
|
Supported by INCA V5.3 and higher, INTECRIO V3.0 and higher, ES400 configuration and integration tool for XCP applications | |
Notes |
|
[1] | 60 V maximum for use inside the US. |
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.