Technical Data

Size and Weight

Dimensions (HxWxD) 52 x 40 x 142 mm / 2.0 x 1.6 x 5.6 in (total)
39 x 40 x 63 mm / 1.5 x 1.6 x 2.5 in (tapered rear)
Weight 350 g / 0.77 lb

Environment

Temperature range -40 °C to +120 °C (-40 °F to +248 °F) (operation)
-40 °C bis +125 °C (storage)
Protection class IP67
Altitude Deployable up to 5,000 m /16,400 ft
Tested for Mechanical shock, vibration, fall, temperature shock, temperature alteration, storage in humid-ity, salt fog attack, impact from flying rocks, according to DIN EN 60068 res. ISO 16750

Power supply

Operating voltage 5 V to 50 V DC (-40 °C to +85 °C / -40 °F to +185 °F),
6 V to 50 V DC (+85 °C to +120 °C / +185 °F to +248 °F)
Power consumption (at 12 V) 2 W typ. (operation)
6 W max. (operation with max. sensor supply)
25 mW max. (standby)
Reverse voltage protection, load dump protection Via cables CBEP410 / 415 / 420 / 425 / 430 / 450

Host interface

Ethernet connection and protocol 100 Base-T, Full-Duplex required, XCP-on-UDP/IP
IP address 192.168.40.44 (Default), configurable via INCA or ES400 configuration and integration tool for XCP applications

Inputs

Channels 4, with separate sensor supply
Input measurement ranges (MR) ± 100 mV, ± 1 V, ± 10 V, ± 60 V
Sampling rate 0.5 Samples/s to 100,000 Samples/s, configurable per channel
Anti-aliasing filter (in hardware) Low-pass 4th order Butterworth, 50 kHz corner frequency
Digital filter (Software) Low-pass 2nd order CIC (moving average)
Overvoltage protection [1] ±100 V (Input to external overvoltage)
Maximum isolation voltage [1] 100 V DC (Input to input or input to supply voltage ground or housing)
Input impedance > 2 MΩ II < 400 pF (± 10 V, ± 60 V)
> 10 MΩ II < 300 pF ( ± 1 V, ± 100 mV)

Accuracy

Resolution 3,6 μV (MB: ± 100 mV)
37,2 μV (MB: ± 1 V)
366 μV (MB: ± 10 V)
2,16 mV (MB: ± 60 V)
Measurement error ± (100 μV + |Uin| * 0,1%) (MB. ± 100 mV)
± (500 μV + |Uin| * 0,05%) (MB: ± 1 V)
± (3 mV + |Uin| * 0,05%) (MB: ± 10 V)
± (16 mV + |Uin| * 0,2%) (MB: ± 60 V)
Temperature drift (-40 °C bis 85 °C) 8 μV/K (MB: ± 100 mV)
8 μV/K (MB: ± 1 V)
36 μV/K (MB: ± 10 V)
3,6 mV/K (MB: ± 60 V)
Temperature drift (85 °C bis 120 °C) 150 μV/K (MB: ± 100 mV)
150 μV/K (MB: ± 1 V)
360 μV/K (MB: ± 10 V)
3,6 mV/K (MB: ± 60 V)

Sensor supply output

Output voltage 0 V, 5 V to 15 V DC, individually configurable per channel
Accuracy of output voltage ± 10 mV
Output current 30 mA max. per channel
Diagnostics Overload warning by LED and in the software

Support by ETAS Software

Supported by INCA V7.0 and higher, ES400 configuration and integration tool for XCP applications V1.4.0 and higher, ASCET-RP V6.1.3 and higher, INTECRIO Integration Platform V4.2 and higher, INTECRIO-RLINK V1.0 and higher, HSP Update-Tool V10.0.0 and higher

System requirements

Computer with Dual-Core I5 or similar, 2,5 GHz, built-in gigabit network controller

Notes

[1] 60 V maximum for use inside the US.

This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.