Technical Data

ES4435 Current Source Load Board

Number of channels 24
Max. load current 150 mA

ES4450 Load Board Solenoid injector CRS

Number of channels 4
Max. load current (at VBat) 20 A
Max. load voltage 60 V DC

ES4451 Load Board Solenoid injector GDI

Number of channels 4
Max. load current (at VBat) 20 A
Max. load voltage 60 V DC

ES4452 Load Board for 4 RB GDI Injectors, CVO

Number of channels 4
Max. load current 20 A (max. 50 W rms (root meansquare))
Max. Duty Cycle 25 %
Max. load voltage 100 V (max. 50 W rms (root meansquare))

ES4455 Load Board

Number of channels 4
Max. load current (at VBat) 20 A
Max. load voltage 60 V DC

ES4456 Load Board Piezo injector CRS

Number of channels 8
Max. load current (at VBat) 16 A
Max. load voltage 250 V DC

ES4457 Load Board for 4 RB CRS Injectors, VCC and VCA

Number of channels 4
Max. load current 20 A (max. 50 W rms (root meansquare))
Max. Duty Cycle 25 %
Max. load voltage 100 V (max. 50 W rms (root meansquare))

ES5450 Load carrier Board for 4 RB CRI2x Injectors

Number of channels 4
Max. load current (at VBat) 20 A
Max. load voltage 60 V DC

ES5451 Load board for four injectors in Bosch HDEV5 gasoline direct injection systems

Number of channels 4
Max. load current (at VBat) 20 A
Max. load voltage 60 V DC

ES5452 Load board for four injectors in Bosch HDEV5 gasoline direct injection systems

Number of channels 4
Max. load current (at VBat) 20 A (max. 50 W rms (root meansquare))
Max. Duty Cycle 25 %
Max. load voltage 100 V (max. 50 W rms (root meansquare))

ES5453 Load board for four injectors in Bosch HDEV6 gasoline direct injection systems

Number of channels 4
Max. load current 20 A (max. 50 W rms (root meansquare))
Max. Duty Cycle 25 %
Max. load voltage 100 V (max. 50 W rms (root meansquare))

ES5455 Load board device with four channels for certain load simulations (up to 60 V DC and 20 A at VBat)

Number of channels 4
Max. load current (at VBat) 20 A
Max. load voltage 60 V DC

ES5457 Load board for four solenoid valve injectors in the Bosch common-rail system

Number of channels 4
Max. load current 20 A (max. 50 W rms (root meansquare))
Max. Duty Cycle 25 %
Max. load voltage 100 V (max. 50 W rms (root meansquare))

ES5458 Load board for four injectors in Bosch EV14 fuel injection systems

Number of channels 4
Max. load current 20 A (max. 50 W rms (root meansquare))
Max. Duty Cycle 25 %
Max. load voltage 100 V (max. 50 W rms (root meansquare))

This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.