Technical Data

Size and Weight

Dimensions (HxWxD) 45 mm x 127 mm x 160 mm / 1.75 in x 5.0 in x 6.3 in (housing)
Weight 0,8 kg / 1.8 lbs

Environment

Temperature range -40 °C to +70 °C (-40 °F to +158 °F) (operation)
-40 °C to +85 °C (-40 °F to +185 °F) (storage)
Relative humidity 15 % to 95 %, non-condensing
Electrical isolation All interfaces are electrically isolated

Power supply

Operating voltage 7 V to 29 V DC
Power consumption (at 14,4 V) 500 mA typical at 14,4 V (typical, operation)
20 mA typical at 14,4 V (typical, stand-by)
Power management (wake-up / stand-by) Power-on/off when Ethernet traffic starts/stops (PC or upstream module on/off), power-on when data traffic on CAN starts
Protection Reverse voltage protection, load dump protection

CAN FD / CAN interface

Number of channels 4
Mode of operation CAN FD or CAN operation can be configured for each port individually by software. 2 channels provide wake-up on CAN functionality.
Protocols CCP (not on CAN FD), XCP, KWP-on-CAN (ISO 14230/ISO 15765), UDS (ISO 14229/ISO 15765), CAN Monitoring, OBD-on-CAN (ISO 15765-4)
Maximum baud rate on CAN 1 Mbit/s
Maximum baud rate on CAN FD 5 Mbit/s (at optimum environmental conditions higher baud rates are possible)
Transceiver (Physical Layer) TJA1044G

Ethernet interface

Number of channels 1 upstream channel
3 downstream channels
Connection and protocols 10/100 Base-T, TCP/IP
Time synchronization Time resolution: 1 µs
Power supply of connected downstream devices ES4xx and ES6xx measurement modules, maximum 2 A per interface independent of the power supply voltage

Status display

LEDs Operation, interfaces, synchronization

Compatible hardware

PC / Upstream ETAS Module Desktop or Laptop-PC with Ethernet port, ES51x, ES592, ES593-D, ES595, and ES600 Network and Interface Modules
Downstream ETAS Module ES520, ES590, ES591, ES592, ES593-D, ES595, and ES600 Network and Interface Modules, ES4xx and ES6xx Measurement Modules, ES910 Prototyping and Interface Module, ES930 Multi I/O Module, XETK

This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.