XETK-T2.2

 
 

CPU interface

Bus interface 2.5 V/3.3 V (auto-detect) bus interface for non-multiplexed bus
32 bit
Supported processors For Infineon TC1792, TC1793, TC1793_ED, TC1796, TC1796ED, TC1797 and TC1797ED processors
For a complete list of supported microprocessors, please refer to the product's User's Guide.
Configuration Project-specific configuration for memory configurations stored in EEPROM

Board

Dimensions (HxWxD) 9.9 x 76 x 58 mm/ 0.39 x 2.992 x 2.283 in

Power supply

Input voltage 4.3 V to 18 V
Stand-by: min. 4.3 V
Input current at 12 V approx. 100 mA normal operation
approx. 20 mA stand-by

Memory emulation

Emulation memory Two memory pages with 1 MB (1024 KB) data memory each, minimum access time 18 nsec
Measured data memory Within the emulation memory, freely configurable
Flash memory 1024 KB flash (data)

Host interface

Serial interface 100 Mbit/s
Double-shielded line, max. 30 m/100 ft
Electrically isolated
Debug interface JTAG debugging interface connector

Operation temperature

Temperature range -40 °C to +110 °C /-40 °F to +230 °F

This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.

Ordering Information

1 – Ethernet PC Connection
2 – Ethernet PC Connection - Adapter Cable
3 – Ethernet ES600 Connection - Adapter Cable
4 – Ethernet ES910 Connection
5 – XETK Connection
6 – Power Supply Connection
7 – ECU Connection

Order Name Short Name Order Number
XETK-T2.2
XETK-T2.2C emulator probe for a TC1792, TC1793, TC1796 or TC1797 ECU, with 1 MByte emulation RAM and a 416 pin ECU-adapter, with BDR support via JTAG XETK‑T2.2C F‑00K‑107‑446 F00K107446 F-00K-107-446
Optional Accessories for XETK-T2.2
1 – Ethernet PC Connection
Ethernet PC Connection Cable 1 Gbit/s, Lemo 1B FGE - RJ45 (10mc-8mc), 3 m CBE200‑3 F‑00K‑104‑373 F00K104373 F-00K-104-373
Ethernet PC Connection Cable 1 Gbit/s, Lemo 1B FGE - RJ45 (10mc-8mc), 8 m CBE200‑8 F‑00K‑104‑374 F00K104374 F-00K-104-374
2 – Ethernet PC Connection - Adapter Cable (CBE230-PC)
Ethernet Connection Adapter Cable 1 GBit/s, Lemo 1B PHE - RJ45 (10fc- 8mc), 1m2 CBAE200‑1m2 F‑00K‑105‑760 F00K105760 F-00K-105-760
3 – Ethernet ES600 Connection - Adapter Cable (CBE230-ES600)
Ethernet Connection Adapter Cable 1 GBit/s to 100 MBit/s, Lemo 1B PHE - Lemo 1B FGF (10fc-8mc), 0m5 CBAE330‑0m5 F‑00K‑105‑759 F00K105759 F-00K-105-759
4 – Ethernet ES910 / ES592 / ES595 Connection
Ethernet Connection Cable 1 GBit/s, Lemo 1B FGE - Lemo 1B FGE (10mc- 10mc), 3 m CBE230‑3 F‑00K‑105‑757 F00K105757 F-00K-105-757
Ethernet Connection Cable 1 GBit/s, Lemo 1B FGE - Lemo 1B FGE (10mc- 10mc), 8 m CBE230‑8 F‑00K‑105‑758 F00K105758 F-00K-105-758
5 – XETK Connection
XETK ECU Adapter Cable, 100 Mbit/s, Shield on ECU-Housing, Lemo 1B HME - JST PHR (10fc-5fc), 0m38 CBAM230‑0m38 F‑00K‑105‑791 F00K105791 F-00K-105-791
XETK ECU Adapter Cable, 100 MBit/s, Lemo 1B PHE - JST PHR (10fc-5fc), 0m6 CBAM240‑0m6 F‑00K‑105‑792 F00K105792 F-00K-105-792
XETK ECU Adapter Cable, pre-assembled into PG9 screwing, shield on ECU- Housing, Lemo 1B PHE - JST PHR (10fc-5fc), 0m50 CBAM271‑0m5 F‑00K‑107‑867 F00K107867 F-00K-107-867
5&6 – XETK and Power Supply Connection
XETK ECU Adapter and Power Supply Cable, pre-assembled into PG9 screwing, shield on ECU-Housing, Lemo 1B PHE - JST PHR (10fc-5fc) / Lemo 0B PHG - JST PAP (2fc-2fc), 0m50 CBAM270‑0m5 F‑00K‑107‑866 F00K107866 F-00K-107-866
XETK ECU Adapter and Power Supply Cable, pre-assembled into PG9 screwing, shield on ECU-Housing, Lemo 1B PHE - JST PHR (10fc-5fc) / Lemo 0B PHG - JST PAP (2fc-2fc), 0m70 CBAM270‑0m7 F‑00K‑108‑479 F00K108479 F-00K-108-479
6 – Power Supply Connection
ETK Power Supply Cable, JST PHR - open wires (2fc-2c), 0m19 ETV Y‑261‑A24‑446 Y261A24446 Y-261-A24-446
ETK Power Supply Cable for External Supply, with Filter Coil, Lemo 0B EGG - open wire (2fc-1c), 0m2 KA50 F‑00K‑000‑940 F00K000940 F-00K-000-940
External Power Supply Cable for ETKs, Lemo 0B - FGG open wires (2fc-1c), 2 m K70.1 F‑00K‑109‑270 F00K109270 F-00K-109-270
7 – ECU Connection To connect the XETK with the ECU, no additional cable is required.
ECU Connection Protection Cap (for CBAM230, CBAM240)
Cap to protect open Lemo 1B sockets against dirt, cost effective CAP_LEMO_1B_LC F‑00K‑105‑683 F00K105683 F-00K-105-683