ES410
ES410 – A/D module
The ES410 is an A/D module with 8 electrically isolated channels. Compared to the ES411 module, it offers 4 additional input channels but no sensor supply. The ES410 module has 8 input voltage ranges between ±100 mV and ±60 V.ES410 input signals can be passed through a high quality configurable FIR filter of 8th order to suppress signal noise and avoid aliasing effects. Signal oversampling is supported by independent setting of corner frequency and sampling rate. For best measurement results also at low sample rates, the FIR filter is always using all availa
Your benefits
- 8 electrically isolated A/D (analog input) channels
- Input voltage range between ±100 mV and ±60 V
- Sampling rates between 0.5 Hz and 10 kHz
- Software configurable high-order low-pass filter
- Operating temperature between -40 °C and 120 °C (-40 °F and 248 °F)
- Rugged water and dustproof housing (IP67)
- Cost effective
Technical data
| Size and Weight | |
|
Size and Weight
Dimensions (HxWxD)
|
51.5 x 40 x 142 mm / 2.0 x 1.6 x 5.6 in
37.5 x 40 x 129 mm / 1.5 x 1.6 x 5.1 in (tapered rear) |
|
Size and Weight
Weight
|
350 g / 0.77 lb
|
|
Size and Weight
Environment
|
|
|
Size and Weight
Temperature range
|
-40 °C to +120 °C (-40 °F to +248 °F) (operation)
|
|
Size and Weight
|
-40 °C to +125 °C (-40 °F to +257 °F) (storage)
|
|
Size and Weight
Protection class
|
IP67 (with cables connected)
|
|
Size and Weight
Altitude
|
Up to 5,000 m / 16,400 ft
|
|
Size and Weight
Tested for
|
Mechanical shock, vibration, fall, temperature shock, temperature alteration, storage in humidity, salt fog attack, impact from flying rocks, according to DIN EN 60068 res. ISO 16750
|
|
Size and Weight
Power supply
|
|
|
Size and Weight
Operating voltage
|
5 V to 50 V DC (-40 °C to +85 °C / -40 °F to +185 °F),
|
|
Size and Weight
|
6 V to 50 V DC (-40 °C to +120 °C / -40 °F to +248 °F)
|
|
Size and Weight
Power consumption (at 12 V)
|
2.1 W typ., < 25 mW (stand-by)
|
|
Size and Weight
Reverse voltage protection; Load dump protection
|
Via Cables CBEP410 / 415 / 420 / 430 / 450, CBE400
|
|
Size and Weight
Host interface
|
|
|
Size and Weight
Ethernet connection and protocol
|
100 Base-T, Full-Duplex required, XCP-on-UDP/IP
|
|
Size and Weight
IP address
|
Dynamic via INCA or configuration tool
|
|
Size and Weight
|
(default 192.168.40.44)
|
|
Size and Weight
Inputs
|
|
|
Size and Weight
Channels
|
8
|
|
Size and Weight
Input measurement ranges (MR)
|
±100 mV, ±1 V, ±10 V, ±60 V for differential input voltage Vin
|
|
Size and Weight
Over voltage protection
|
±100 V continuous, all MR
|
|
Size and Weight
Resolution
|
16 bit
|
|
Size and Weight
Sampling rate
|
0.5 Samples/s to 10 kSamples/s, configurable per channel
|
|
Size and Weight
Anti-aliasing filter (in hardware)
|
4th order Butterworth, 10 kHz corner frequency
|
|
Size and Weight
Software filter
|
Digital FIR Butterworth 8th order, bypass possible, 5 kHz max. corner frequency
|
|
Size and Weight
Electrical isolation of inputs
|
Channel to channel and channel to supply
|
|
Size and Weight
Max. common mode voltage
|
±(100 V - [Vin]) channel to supply ground, [1]
|
|
Size and Weight
|
Vin ≤± 60 V
|
|
Size and Weight
Input impedance
|
> 2 MΩ II < 2 nF (±10 V, ±60 V)
|
|
Size and Weight
|
> 10 MΩ II < 2 nF (±1 V, ±100 mV)
|
|
Size and Weight
Accuracy (up to +85 °C / +185 °F)
|
|
|
Size and Weight
Measurement error (MR: 100 mV)
|
±[0.15 % + 100 ppm/K x |T -25 °C|] x MR ±0.12 % x Vin
|
|
Size and Weight
Measurement error (MR: 1 V)
|
±[0.05 % + 10 ppm/K x |T - 25 °C|] x MR ±0.1 % x Vin
|
|
Size and Weight
Measurement error (MR: 10 V)
|
±[0.03 % + 5 ppm/K x |T - 25 °C|] x MR ±0.1 % x Vin
|
|
Size and Weight
Measurement error (MR: 60 V)
|
±[0.027 % + 60 ppm/K x |T -25 °C|] x MR ±0.22 % x Vin
|
|
Size and Weight
Support by ETAS Software
|
|
|
Size and Weight
|
Supported by INCA V5.4.1 and up via add-on (part of ES410 delivery), INTECRIO V3.x, ES400 configuration and integration tool for XCP applications
|
Contact us